Standard
Habonim Ball Valves, with no special preparation can effectively be
used in vacuum service down to 20 microns. When Higher Vacuum Service
is required, valves specially prepared, can be used down to 10-6
mm of mercury.
Valves
for Higher Vacuum Service, would require to have all the valve
components -"CLEAN", "DRY ASSEMBLED","TESTED",
"BAGGED AND SEALED IN POLYETHYLENE BAGS" with "SILICA
GELS" and clearly marked for Vacuum Service.
To
avoid confusion as a result of the various ways of measuring Vacuum
Service, some of the more common measurements are given below.
LOW
VACUUM - 760 TORR to 200 TORR
MEDIUM VACUUM - 200 TORR to 1 TORR.
HIGH VACUUM - Down to 10-6 TORR (0.000001 mm Hg).